Telonic TEST

ETL Hi Pot Tester UX36-AC-10-0050-TPT 10kV AC 50mA Flash Tester

ETL UX36-AC-10-0050-TPT Safety Tester Technical Parameters: – test voltage adjustable from 0,5 … 10 kV AC- trip current adjustable from 0,5 … 50 mA- test time adjustable from 1 s – 99 min, endless- nominal capacity of transformer 500 VA- Dimensions (WxHxD): 590 x 210 x 420 mm Technics and common dates:- desktop unit with […]

SKU: UX36-AC-10-0050-TPT
Category: ,

Description

ETL UX36-AC-10-0050-TPT Safety Tester

Technical Parameters:
– test voltage adjustable from 0,5 … 10 kV AC- trip current adjustable from 0,5 … 50 mA- test time adjustable from 1 s – 99 min, endless- nominal capacity of transformer 500 VA- Dimensions (WxHxD): 590 x 210 x 420 mm

Technics and common dates:- desktop unit with dry transformer- potential free (for operation with test pistols)- regulated test voltage, electromechanic- test voltage only be switched on or off in zero voltage run- test voltage sinusoidal with 50 Hz, depending on mains supply- ramp function- burn function for max. 1 second- high voltage outlets backside- conforms to CE standards, as detailed in EN 50 191, potential free- incl. manufacturers certificate of calibration, plug for safety circuit, set of keys.

Features:

  • Large LED-display to display all estimated and true values
  • Optical and acoustic fault indication
  • 15 program memories for pre-defined sets of parameters
  • perfected periphery equipment for PLC, RS232, CAN, driver
  • Data management program and print function only with external PC
  • Optionally available: PC-driver for customer own applications (DLL,Active-X and LabView)
  • Optional customized extensions possible
  • Digital interface for status display and remote control
  • Connection for safety circuit and warning lights as detailed in EN 50191

Additional information

Documents

UX36-DC-10-0050

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.