Telonic TEST

Category: Blog

  • Rental / Hire Bidirectional DC Power Supplies

    Hire Bidirectional DC Power Supplies Telonic UK

    Bidirectional DC power Supplies are fast becoming the go to power supply for all Motor, Powertrain, Inverter and Battery Testing as they combine a DC power supply and DC electronic Load in one box.

    Telonic have increased our Rental / Hire inventory of DC power Supplies to now include all Bidirectional DC Power Supplies from Delta Elektronika.

    Bidirectional DC power Supplies Models available for Rental / Hire Include:

    SM 70-CP-450 (Bi-directional operation)
    Voltage 0 – 70 V  Current -450 .. 450 A

    SM 500-CP-90 (Bi-directional operation)
    Voltage 0 – 500 V Current -90 .. 90 A

    SM 210-CP-150 (Bi-directional operation)
    Voltage 0 – 210 V-150 .. 150 A

    SM 1500-CP-30 (Bi-directional operation)
    Voltage 0 – 1500 V Current -30 .. 30 A

    Need a Higher Power Bidirectional DC power Supply:

    All of the Bidirectional Supplies shown above have a maximum input and output capability of 15kW, however this can be expanded by running multiple units in parallel.

    Bidirectional DC power Supplies Applications Include:

    Batteries
    Super capacitors
    Fuel Cells
    Electrical Energy Storage Devices
    Car testing systems
    E-Drive Powertrains
    Solar inverter testing
    PV-Simulation
    Plasma Surface Technology
    Aerospace and military equipment
    Controlled battery discharging

     

    How much does it cost to Rent or Hire a Bidirectional DC power Supply ?

    Telonic’s rental / hire costs are among the most competitive in the industry, all charges are shown on our website and can be found using the following links.

    SM 70-CP-450 (Bi-directional operation)
    Voltage 0 – 70 V  Current -450 .. 450 A

    SM 500-CP-90 (Bi-directional operation)
    Voltage 0 – 500 V Current -90 .. 90 A

    SM 210-CP-150 (Bi-directional operation)
    Voltage 0 – 210 V-150 .. 150 A

    SM 1500-CP-30 (Bi-directional operation)
    Voltage 0 – 1500 V Current -30 .. 30 A

     

    Standard features for these Bidirectional power supplies is Delta’s new Power Recovery [Regeneration] Technology: in sink mode they can return full power back into the grid and, thanks to an efficiency of 95%, there is no need for expensive water cooling systems. The flexible output covers the output range of five separate power supplies with a traditional rectangular VI-curve.

  • Residual Current Monitoring

    Any electrical leak can be lethal and dangerous for your staff and production site. By using Danisense Residual Current Monitor (RCM) you can protect both staff and equipment, avoid expensive breakdowns – and, even mandatory inspections. Furthermore, you can now get the Smart RCM with PC software for data analysis providing additional monitoring features.

    With the multiplication of power electronic devices used in industrial and commercial installations creating DC and high-frequency residual current, the traditional type A residual current device could achieve its limits and not work properly.

    Thanks to its zero-flux technology expertise, Danisense developed a range of highly flexible Residual Current Monitor of Type B/B+ for measuring DC and AC residual currents up to 100kHz, with analogue 4-20mA and relay output.

    Danisense Residual Current Monitoring – RCM is characterised by

    ·       Large aperture (70 mm).

    ·       Setting of

    – Rated RC limit (30, 100, 300, 500 and 1,000 mA).

    – Frequency range (100, 2,000, 20,000 and 100,000 Hz).

    – Integration time (Short, Medium, Long).

    • Rated residual operating current in combination with full compliance with the new norm IEC62020-1.
    • Locally or remotely operated.

    New: Smart Residual Current Monitoring – RCM with PC software for data analysis

    The latest version of Danisense RCM is controlled by PC (via USB) for data analysis and provide you with the following additional monitoring features:

    • FFT (Fast Fourier transform): The frequency spectrum of the measurement.
    • TRMS calculation for the individual low-frequency pass windows selected by you. TRMS is calculated very accurately via the FFT. Typically used for setting the rated RC limit and frequency range.
    • Remote setting of

    – Rated RC limit

    – Frequency range

    – Integration time

    • Time logs off TRMS and relays data.
    • Relay trigger info – for instance, info about last time the residual current has been overdue.
    • General info for the selected settings.

    In Germany, it is mandatory to test and validate production facilities at least every 4 years. Unless the company has Residual Current Monitoring (RCM) installed.

     

    Daninsense Software - Telonic 2

     

    The Info window gives a good overview with several individual options. Always shown are remote settings of the rated RC limit, frequency range, and integration time.

    Another feature is ”Device info” showing supply voltage, temperature, and firmware version. Furthermore, serial number and individual naming of device locations.

    Also, testing of the relay is a direct option.

    Danisense software FFT window - Telonic UK

    The FFT window shows the frequency spectrum of the measurement and corresponds to TRMS calculations of the frequency ranges. Top: Time domain of the measurement.

    Mid: Shows Ranges and TRMS.

    Bottom: The frequency domain spectrum

    Other features include a copy to the clipboard and log / linear scale.

    Danisense software data logging window - Telonic UK

    Data logging shows time logged off TRMS data and relay status. Among the features, other features are “copy to clipboard”.

    How does residual current monitoring work?

    A Residual Current protective Device (RCD) has been a standard component in electrical sub-distribution for many decades. There is also an RCD at home, which has a rated residual current of 30 mA. Tripping between 50 and 100 % of the rated residual current is specified in the international standard. If the 30 mA RCD trips, a residual current must be bigger than 15 mA. The threshold of 30 mA is intended to ensure personal protection, which is required wherever freely accessible sockets are available. Currents from 50 mA onwards are life-threatening.

    In the manufacturing industry environment, we usually find larger machines that are used for production. Even if these machines do not have any freely accessible sockets, RCDs are often used for different safety issues. They are designed to provide safety for three types of protection which are described in the following table.

    Danisense Table -Telonic UK

     

    A system failure can lead to electrical fires. Major damage to the system could also be prevented if a minor defect could be detected at an early stage. A major disadvantage when protecting the systems with an RCD is then an unforeseeable sudden shutdown of the system. In some branches of industry, an uncontrolled and unexpected system shutdown can quickly result in costs in the five to six-figure range.

    This is remedied by Residual Current Monitors (RCM) with which the residual current can be measured. An increase in the residual current can be detected and reported at an early stage. A controlled shutdown of the production plant guarantees better-coordinated repair measures. The availability of the system can be increased. The probability of a production downtime decreases. An RCM is part of predictive maintenance.

    Danisense RCD vs RCM Telonic UK

     

    The figure above clearly shows that, in contrast to the RCD, an RCM cannot independently interrupt the supply line. The differential current is only measured and outputted via a suitable interface. In addition, RCMs have one or more relay outputs, which in turn can be used to control circuit breakers.

     

     

    Which standard must a residual current monitoring device comply with?
    Residual current monitoring devices can offer significant added value for any company with electrical installations. As mentioned in the IEC 60364-6:2016 there has to be a periodic verification of electrical installations or productions plants. This periodic verification is described as follows:

    6.5.1.2 Periodic verification shall be carried out without dismantling, or with partial dismantling, as required, supplemented by appropriate tests and measurements from Clause 6.4, to provide for:

    the safety of persons and livestock against the effects of electric shock and burns,
    protection against damage to property by fire and heat arising from an electrical installation defect,
    confirmation of correct rating and setting of protective devices required by IEC 60364-4-41,
    confirmation of correct rating and setting of monitoring devices,
    confirmation that the installation is not damaged or deteriorated to impair safety,
    the identification of installation defects and non-compliance with the requirements of the relevant parts of the IEC 60364 series, that may give rise to danger,
    confirmation of correct rating and setting of protective devices, and
    confirmation of correct rating and setting of monitoring devices.

    Where a circuit is permanently monitored by a residual current monitoring device (RCM) in accordance with IEC 62020 or an IMD in accordance with IEC 61557-8 it is not necessary to measure the insulation resistance if the function of the IMD or RCM is correct.

    The functioning of the RCM or IMD shall be verified.
    As we can see it is expressly stated that measurement of the insulation resistance in the periodic verification can be replaced by a residual current monitoring device in accordance with high-frequency now read the IEC 62020 which monitors permanently the residual current in conjunction with continuous maintenance by qualified electricians.

    Another area of application of the RCM is the protection of production plants against fire. Around 30 percent of all registered fires can be traced back to faults or defects in electrical systems. The protection via an RCD with 300 mA can often lead to false tripping due to the very high system-related residual currents of the system. This is where the IEC 60364-4-42:2010+AMD1:2014 comes into play, stating that residual current monitors may be used in conjunction with a circuit breaker to avoid electrically ignited fires due to insulation faults to shut down the system if residual current protective devices (RCDs) are ruled out for technical reasons.

    As a result, it is strongly advised to use residual current monitors in accordance with the IEC 62020 in order to exploit all the benefits you can achieve with these devices.

     

    Danisense RCMH070IB+ Residual Current Monitoring

     

    Other Current Transducers from Danisense.

    Voltage Output Models

    Model Range AC Current DC Current Bandwidth OVERALL ACCURACY DC-10Hz @ 25°C Output Ratio Output Connections Price
    DS50UB-1V 100A 50Arms 75A >500kHz 121ppm 1V / 50A BNC Plse Call
    DS50UB-10V 55A 36Arms 50A >500kHz 149ppm 10V / 50A BNC Plse Call
    DS200UB-1V 330A 200Arms 300A >500kHz 60ppm 1V / 200A BNC Plse Call
    DS200UB-10V 220A 140Arms 200A >500kHz 54ppm 10V / 200A BNC Plse Call
    DS300UB-10V 330A 210Arms 300A >500kHz 45ppm 10V / 300A BNC Plse Call
    DS400UB-10V 440A 280Arms 400A >500kHz ??? 10V / 400A BNC Plse Call
    DS600UB-1V 950A 600Arms 900A >300kHz 42ppm 1V / 600A BNC Plse Call
    DS600UB-10V 660A 424Arms 600A >300kHz 43ppm 10V / 600A BNC Plse Call
    DS1000UB-10V 1100A 700Arms 1000A >300kHz 54ppm 10V / 1000A BNC Plse Call
    DL2000UB-1V 3000A 2000Arms 3000A >300kHz 50ppm 1/2000V/A BNC Plse Call
    DL2000UB-10V 2200A 1414Arms 2000A >300kHz 50ppm 1/200V/A BNC Plse Call
    DM1200UB-10V 1320A 850Arms 1200A >300kHz 35ppm 10V / 1200A DSUB9 male & BNC Plse Call
    DR5000UX-10V/7500A 8000A 5000Arms 7500A >100kHz 20ppm 1V / 750A Mini XLR Plse Call
    DR10000UX-10V 11000A 7000Arms 10000A >100kHz 20ppm 1V / 1kA Mini XLR Plse Call
    RCMH070IB+ Plse Call

    Current Output Models

    Model Range AC Current DC Current Bandwidth OVERALL ACCURACY DC-10HZ @ 25°C Primary / Secondary Ratio Output Connections PRICE
    DC200IF 300A 200Arms 300A >500kHz 11ppm 1 : 1000 6.3mm x 0.8mm Faston
    DS50ID 150A 50Arms 75A >1MHz 88ppm 1 : 500 DSUB9 Plse Call
    DS200ID 370A 200Arms 300A >1MHz 22ppm 1 : 500 DSUB9 Plse Call
    DS200ID-CD100 370A 200Arms 300A 1MHz 22ppm 1 : 500 DSUB9 Plse Call
    DS200ID-CD1000 370A 200Arms 300A 1MHz 22ppm 1 : 500 DSUB9 Plse Call
    DS300ID 500A 300Arms 450A >1MHz 15.5ppm 1 : 1000 DSUB9 Plse Call
    DS400ID 600A 400Arms 600A 300kHz 18.17ppm 1 : 2000 DSUB9 Plse Call
    DQ500ID 800A 500Arms 750A >300kHz 11ppm 1 : 1750 DSUB9 Plse Call
    DS600ID / DQ600ID 1000A 600Arms 900A >500kHz 9.33ppm 1 : 1500 DSUB9 Plse Call
    DS600ID-CD100 1000A 600Arms 900A 500kHz 11ppm 1 : 1500 DSUB9 Plse Call
    DQ600ID-P1300 1300A 600Arms 900A 300kHz 11ppm 1 : 1500 DSUB9 Plse Call
    DQ640ID-B 640A 28 to 452Arms 40A to 640A >300kHz 13ppm Progr 40A-640A DSUB9 Plse Call
    DL2000ID 3000A 2000Arms 3000A >300kHz 7ppm 1 : 1500 DSUB / BNC Plse Call
    DL2000ID-CB100 3000A 2000Arms 3000A 300kHz 7ppm 1 : 1500 DSUB9 Plse Call
    DL2000ID-CD100 3000A 2000Arms 3000A 300kHz 7ppm 1 : 1500 DSUB9 Plse Call
    DM1200ID 1800A 1200Arms 1500A 400kHz 11ppm 1 : 1500 DSUB9 Plse Call
    DM1200ID-CD3000 1800A 1200Arms 1500A 15kHz 15ppm 1 : 1500 DSUB9 Plse Call
    DR5000IM 8000A 5000Arms 8000A >100kHz 4ppm 1 : 2500 4mm Banana Plse Call
    DR10000IM 11000A 7000Arms 10000A >100kHz 6ppm 1 : 2500 4mm Banana Plse Call

    PCB Mount

    Model Measurement Resistor Linearity Error Weight Height PRICE
    DP50IP-B Up to 100Ω at full scale 10ppm 250g 32mm Plse Call
  • TELONIC BLACK FRIDAY 2021 DEALS

    TELONIC BLACK FRIDAY 2021 DEALS

    TEST AND MEASUREMENT BLACK FRIDAY DEALS

     

    ENJOY UP TO 10% OFF OF ALL TEST & MEASUREMENT  AND POWER SUPPLIES WITH THE FOLLOWING DISCOUNT CODES

    BLACK10%

    SPEND OVER £1000 AND SAVE 10% with code BLACK10%

    BLACK7%

    SPEND OVER £500 AND SAVE 7% with code BLACK7%

    BLACK5%

    SPEND OVER £100 AND SAVE 5% with code BLACK5%

    Valid Friday, Saturday, Sunday and Monday

    expires 30 November 2021

    FREE UK SHIPPING ON ORDERS OVER £100

    valid for online orders only on telonic.co.uk

  • Siglent release NEW SNA5000A Vector Network Analyser

    Siglent release NEW SNA5000A Vector Network Analyser

    SIGLENT presents its first vector network analyser and the first device of its new “A” performance line
    With the continuous growth of radio and cellular networks, the increase in data traffic and increasing data rates, the need for high-performance measurement technology is growing. Vector network analysers are a key measuring device in the field of high frequency technology. Measurement of passive or active components, verification of 2-port networks or adaptation of antennas are just a few examples of where VNAs are required. The intuitive operating concept of the SNA5000A makes work easier and faster, and the large screen enables the results to be displayed clearly. The powerful hardware ensures accurate and reliable results.

     

     

     

    July 20, 2021: SIGLENT Technologies presents its first 2- or 4-port vector network analyser. This innovation is an important and significant step for Siglent as the SNA increases Siglent’s product breadth and is the first family of products introduced in the new “A-Line”. This is expressed by the new suffix “A” at the end of each model number. Several more A-series devices will follow in the next 18 months. Compared to the existing, very successful X-series devices, which focus on price-performance, the A-line focuses on quality, reliability and efficiency.

    The SNA5000A network analyser is offered as a 2- or 4-port device with frequency ranges from 9 kHz to 4.5 GHz or to 8.5 GHz. The dynamic range spans 125 dB and enables, for example, a precise analysis of the stopband of a filter without losing sight of the passband. The analysers support 2/4 port S-parameters and differential S-parameter measurements. Time domain analyses can be performed with the options SNA5000-TDA (Time Domain Analysis) or SNA5000-TDR (Advanced Time Domain Analysis).

    The accuracy of a network analyser is very much linked to the accuracy of the calibration. Different calibration techniques are required for different applications. With the SNA5000A, the user can choose between 1-port, extended 1-port, full 2-port correction and the different techniques SOLT, SOLR, TRL in order to obtain the best accuracy for the respective application. An adjustable reference plane, port matching and the embedding / de-embedding of test sockets enable the elimination of external sources of error. The VNAs of the SNA5000A series offer five types of sweeps: linear and logarithmic frequency sweeps, output power sweeps, time domain sweeps and segmented sweeps. The formula editor and the mask test support the developer in the analysis of his test object and accelerate the evaluation and verification.

    The large 12-inch touchscreen can be flexibly configured so that several windows with different measurements can be clearly displayed. The short-cut menu helps with configuration and offers quick access to the most important functions. The device supports an external mouse and keyboard, external monitor via HDMI, and can be controlled via the web interface from the PC.

     

    To view the SNA5000A Category page, please see HERE

  • DC Electronic Load – Part 4: How Each Operation Mode Works with Other Modes?

    We have so far explained the four major operation modes for electronic loads – 1) constant current 2) constant resistance 3) constant voltage and 4) constant power, in the previous white papers. Now this paper describes how these modes relate to each other and how each mode works on other modes.
    4-1. Relationship between Operation Modes
    Figure 4-1 shows the block diagram for the control circuit structure of the electronic loads, where each operation mode is switched by.
    The CC-CR switch closes either path of the constant current (CC) circuit or the constant resistance (CR) circuit. There is the OR circuit connected between the closed circuit (either CC or CR), the constant power (CP) circuit and constant voltage (CV) circuit. You will have the following three factors to determine which circuit is used, CP circuit or CV circuit: 1) the setting value for each control circuit 2) the input voltage of the electronic load and 3) the input current of the electronic load. In addition, the setting of the CV-ON switch determines whether to use the CV circuit or not.
    Therefore, the electronic load users need to set at least the following settings:
    1) Choose the CC mode or the CR mode to be used.
    2) Choose whether to use the CV mode or not.
    3) Set the appropriate settings for each operation mode.

    As stated above, the four operation modes have the relationship with each other and the modes are switched depending on the setting values, the input voltage and the input current of the electronic load. In the next sections, we are going to explain the details how each mode is related and when exactly the modes are switched.
    4-2. How CC Mode is Combined with Other Mode
    Figure 4-2 describes the circuit of the DUT and the electronic load; the components of the DUT are the voltage source (Vs) such as a power supply and the resistance (Rs) connected in series with Vs.
    Figure 4-3 and 4-4 are the characteristic examples of how the input current flows with the Vs change when the CC mode setting of the electronic load is set to 10 A.
    For figure 4-3, the CV mode is turned off. While Vs rises from almost 0 V to Point ‘a’, the electronic load operates in CC mode at 10 A as shown in the red line. After Vs exceeds Point ‘a’, the electronic load operates in CP mode*1 at 150 W as shown in the yellow line.
    For figure 4-4, the CV mode is turned on (CV-ON). If Vs rises from almost 0 V, the input current does not actually exist until Point ‘c’ (= at the CV set value). After Vs exceeds Point ‘c’, the electronic load operates in CV mode until Point ‘b’, but it operates in CC mode after Point ‘b’ to Point ‘a’ at 10 A. After Vs exceeds Point ‘a’, the electronic load operates in CP mode*1 at 150 W as shown in the yellow line.
    *1: Some electronic loads provide the overpower protection (OPP) function instead of the CP mode. The protection function will be described later in another white paper in this series.

    Recommendations and Precautions for Use of CC Mode
    To ensure the reliability of the CC mode operation, read the following advice:
    1) If you want to use the CC mode only, you just set the CC mode setting. Turning off the CV mode is recommended, because if the CV mode is turned on (CV-ON), the input current does not actually exist until the input voltage reaches the CV set value. When setting the CP mode value or the OPP value, set it to the maximum.
    2) The CV mode (CV-ON) can be used as the over-discharge protection for rechargeable batteries. Initially the CC mode starts to discharge the battery until the battery voltage falls to the CV set value. Then, the mode switches from CC to CV and the electronic load stops the input current flow. This prevents the battery voltage from becoming too low to protect against over discharge.
    3) When entering the CC mode, some electronic loads may automatically set the CP mode value to the maximum.
    4-3. How CR Mode is Combined with Other Mode

    For the system circuit, see figure 4-2 above.
    Figure 4-5 and 4-6 are the characteristic examples of how the input current flows with the Vs change when the CR mode setting of the electronic load was set to 1.5 Ω.
    For figure 4-5, the CV mode is turned off. While Vs rises from almost 0 V to Point ‘a’, the electronic load operates in CR mode at 1.5 Ω as shown in the red line. After Vs exceeds Point ‘a’, the electronic load operates in CP mode*2 at 150 W as shown in the yellow line.
    For figure 4-6, the CV mode is turned on (CV-ON). If Vs rises from almost 0 V, the input current does not actually exist until Point ‘c’ (= at the CV set value). After Vs exceeds Point ‘c’, the electronic load operates in CV mode until Point ‘b’, but it operates in CR mode after Point ‘b’ to Point ‘a’ at 1.5 Ω. After Vs exceeds Point ‘a’, the electronic load operates in CP mode*2 at 150 W as shown in the yellow line.
    *2: Some electronic loads provide the overpower protection (OPP) function instead of the CP mode. The protection function will be described later in another white paper in this series.

    Recommendations and Precautions for Use of CR Mode
    To ensure the reliability of the CR mode operation, read the following advice:
    1) If you want to use the CR mode only, you just set the CR mode setting. Turning off the CV mode is recommended, as stated above in ‘Recommendations and Precautions’ of Section 4-2. When setting the CP mode value or the OPP value, set it to the maximum.
    2) The CV mode (CV-ON) can be used as the over-discharge protection for rechargeable batteries. For this CV mode operation, refer to ‘Recommendations and Precautions’ of Section 4-2. *Read as changing the CC mode to the CR mode.
    3) When entering the CR mode, some electronic loads may automatically set the CP mode value to the maximum.

    4-4. How CP Mode is Combined with Other Mode For the system circuit, see figure 4-2 above.
    Figure 4-7 and 4-8 are the characteristic examples of how the input current flows with the Vs change when the CP mode setting of the electronic load was set to 100 W.
    For figure 4-7; the CV mode is turned off, and the CC mode or the CR mode is set to Automatic or the maximum rating value. If Vs rises from almost 0 V to Point ‘a’, the electronic load operates in CC mode at 15 A (rating current) as shown in the red line. After Vs exceeds Point ‘a’, the electronic load operates in CP mode at 100 W as shown in the yellow line and it may reach Point ‘c’ with Vs change.
    For figure 4-8, the CV mode is turned on (CV-ON). While Vs rises from almost 0 V, the input current does not actually exist until Point ‘a’ (= at the CV set value). After Vs exceeds Point ‘a’, the electronic load operates in CV mode until Point ‘b’. After Vs exceeds Point ‘b’, the electronic load operates in CP mode at 100 W as shown in the yellow line and it may reach Point ‘c’ with Vs change.

    Recommendations and Precautions for Use of CP Mode
    To ensure the reliability of the CP mode operation, read the following advice:
    1) When setting the CP mode value and the CR mode value, set them to the maximum.
    2) If you want to use the CP mode only, you just set the CP mode setting. Turning off the CV mode is recommended, as stated above in ‘Recommendations and Precautions’ of Section 4-2.
    3) The CV mode (CV-ON) can be used as the over-discharge protection for rechargeable batteries. For this CV mode operation, refer to ‘Recommendations and Precautions’ of Section 4-2. *Read as changing the CC mode to the CP mode.
    4) In CP mode, if you do not want a high input current, you can regulate it by setting a lower CC mode value or setting an overcurrent protection (OCP).
    4-5. How CV Mode is Combined with Other Mode For the system circuit, see figure 4-2 above.
    Figure 4-9, 4-10 and 4-11 are the characteristic examples of how the input current flows with the Vs change when the CV mode setting of the electronic load was set to 10 V.
    Figure 4-9 shows the combination between the CV mode and the CC mode. For the CV mode operation, read Section 4-2 describing figure 4-4 ‘the CV mode is turned on (CV-ON)’. The input current does not actually exist until Vs reaches the CV set value. After Vs exceeds Point ‘c’, the electronic load operates in CV mode until Point ‘b’ as shown in the green line. Then, after Vs exceeds Point ‘b’, the mode switches to the CC mode until Point ‘a’. If Vs rises above Point ‘a’, the mode switches to the CP mode*4.
    Figure 4-10 shows the combination between the CV mode and the CR mode. For the CV mode operation, read Section 4-3 describing figure 4-6 ‘the CV mode is turned on (CV-ON)’. Figure 4-10 looks similar to figure 4-9, except that the mode is in the CR mode from Point ‘b’ to Point ‘a’. Figure 4-11 shows the combination between the CV mode and the CP mode. For the CV mode operation, read Section 4-4 describing figure 4-8 ‘the CV mode is turned on (CV-ON)’. While Vs is lower than Point ‘a’ (= at the CV set value), the input current does not actually exist. When Vs exceeds Point ‘a’, the electronic load operates in CV mode until Point ‘b’ as shown in the green
    line. After Vs exceeds Point ‘b’, the electronic load operates in CP mode.
    *3: ‘CV-ON’ can be referred to as ‘+CV’.
    *4: Some electronic loads provide the overpower protection (OPP) function instead of the CP
    mode. The protection function will be described later in another white paper in this series.

    Products Mentioned In This Article:

    Kikusui Electronic Loads please see HERE

  • How to Double Output Voltage from Two PBZ through BTL* Connection

    Here is an introduction on a method to achieve a double output voltage using two units of PBZ. The actual connection of PBZs is shown in Figure 1 as;
    -‘OUT’ terminals are used for output.
    – Only ‘COM’ terminal can be earthed for output, if required.
    For the frequency characteristics, it is limited to 50 kHz in CV (100 kHz in normal) and limited to 8 kHz in CC (10 kHz in normal) as specification. This method enables you to use PBZ as high-speed bipolar power supply for your usage and needs.
    *BTL (Bridged Transformer Less)
    1. Connection Overview:
    PBZ BTL Master (BTL Master) outputs the positive voltage (+V), while PBZ BTL Slave (BTL Slave) outputs the negative voltage (-V) through ‘OUT’ terminal. So, the amount of output voltage on the RL will double (2V).
    How to Connect PBZ:
    1) Connect ‘COM’ terminals to each other.
    2) Connect each ‘OUT’ terminal to RL.
    3) Make sure that rear ‘OUT’ terminal is not connected to ‘GND’ terminal. You can connect rear ‘COM’ terminal to ‘GND’ terminal, if needed.
    4) Connect ‘CV MONITOR (pin 13, 18)’ of J1 Connector on BTL Master (rear side) to ‘EXT SIG IN’ on BTL Slave (front side).
    5) Connect ‘TRIG OUT’ on BTL Master (rear side) to ‘TRIG IN’ on BTL Slave (rear side) to build trigger synchronization.

    2. Settings
    After connecting as shown in Figure 1, please make the settings below.
    Note) It is recommended that you return BTL Master/Slave to the factory default prior to the settings;
    – Switch POWER on while holding down SHIFT key to return to the factory default.

    2-1 Settings for BTL Master
    To synchronize the OUTPUT ON/OFF operation between BTL Master and Slave, set CONFIG [3] (3/7) > SYNCHRONOUS > OPERATION as below (Refer to page 89 of user’s manual):
    (1) Press CONFIG key several times to move to the menu 3/7.
    (2) Specify SYNCHRONOUS > OPERATION > MASTER using the knob.
    (3) The setting is confirmed once ‘MASTER’ is displayed.
    2-2 Settings for BTL Slave
    1) To synchronize the OUTPUT ON/OFF operation between BTL Master and Slave, set CONFIG [3] (3/7) > SYNCHRONOUS > OPERATION as below (Refer to page 89 of user’s manual):
    (1) Press CONFIG key several times to move to the menu 3/7.
    (2) Specify SYNCHRONOUS > OPERATION > SLAVE using the knob.
    (3) The setting is confirmed once ‘SLAVE’ is displayed.
    2) BTL Slave is synchronized with BTL Master and uses ‘CV MONITOR’ as an external signal source via ‘EXT SIG IN’ instead of using its internal signal.
    Set CONFIG [2] (2/7) > SIGNAL SOURCE > SELECT as below (Refer to page 88 of user’s manual):
    (1) Press CONFIG several times to move to the menu 2/7.
    (2) Specify SIGNAL SOURCE > SELECT > EXT using the knob.
    (3) Specify SIGNAL SOURCE > EXT SELECT > BNC using the knob.
    (4) The setting is confirmed once (2) and (3) is specified.
    3) Set the external signal circuit gain and output polarity to produce the negative output (-V). Specify CONFIG [2] (2/7) > SIGNAL SOURCE > EXT GAIN as below (Refer to page 88 of user’s manual):
    (1) Press CONFIG several times to move to the menu 2/7.
    (2) Specify SIGNAL SOURCE > EXT GAIN as:
    PBZ20: -10.0
    PBZ40: -20.0
    PBZ60: -30.0
    PBZ80: -40.0
    The polarity will be inverted by specifying the negative output value.
    (3) The setting is confirmed once (2) and (3) is specified.
    (4) Perform the gain adjustment to exactly match the output between BTL Master and BTL Slave in step 2.

    3. How to Operate
    ・ Turn OUTPUT on/off by BTL Master only.
    ・ Specify the CV/CC value and current limit value by BTL Master only. ・ If used the same rated voltage models, the output voltage will double. ・ Set RESPONSE of BTL Slave to the fastest.
    ・ Apply the connection control to BTL Master, if needed.
    4. Output Results
    4-1 CV Output – Rising/Falling Characteristics

    PBZ40-10 x 2

    4-2 CC Output – Rising/Falling Characteristics

    PBZ40-10 x 2

    5. Precaution in Use and Others
    5-1 Connecting with Different Rated Models
    It is available to connect PBZs with the same rated voltage and different rated voltage. When connecting PBZs with different rated voltage, the output voltage of BTL Slave is specified by the same ratio of those of BTL Master. In fact, the total output voltage will not double.
    E.g.) BTL Master: PBZ40, BTL Slave: PBZ20; If the output voltage from PBZ40 is set to 20V, the output voltage from PBZ20 will be 10V and the total applied voltage on the load will be 30V.
    5-2 Precaution in Measurement
    Please use a differential probe when measuring the output voltage with an oscilloscope. Without a differential probe, the output will be shorted at the oscilloscope probe, and it may be burnt out.
    5-3 How to Achieve CV 100KHz
    As shown in Figure 6, please use PBZs as BTL amplifier.
    Connect a function generator (FG) through ‘EXT SIG IN’ terminals. FG is used as an external signal source to reach your desired output voltage. By using FG, GAIN is set to be negative to invert BTL Slave polarity. To synchronize the OUTPUT ON/OFF operation between BTL Master and Slave, please build trigger synchronization.
    With this method, only ‘COM’ terminals can be grounded.

    Products Mentioned In This Article:

    • PBZ Series please see HERE
  • Useful Functions and Precautions for Using L-Load/C-Load in PCR-LE Series

    1. When Using Inductive Load (L-Load)
    1-1 Soft Start
    A typical L-load is a motor load. E.g.) If using an induction motor load, the startup current can be 5 times (or more) larger than the normal startup current and it flows for several hundred ms.
    In this situation; 1) The motor load becomes inductive. 2) The power factor is approx. 0.5 at peak current.
    PCR-LE Series features the Soft Start function to gradually increase the startup voltage when OUTPUT is turned on. If Soft Start is set to ON in the above situation; 1) The startup current (peak current) decreases. 2) The power factor is approx. 0.65 at peak current. 3) The startup voltage gradually rises for up to 3 seconds.

    1-2 Output Capacity Reduction Due To Power Factor

    As described in the above, the power factor decreases and the higher current flows for several hundred ms with the motor load. Since this period is quite short, it can be considered as the instantaneous peak current. The instantaneous peak current ratio decreases due to the power factor (see the table below).

    2. When Using Capacitive Load (C-Load)
    2-1 Soft Start
    PCR-LE Series supports the DC output mode. In DC mode, the peak current in C-load changes with the voltage rise slope and can be calculated as: I=LdV/dt. Since the voltage rise time of PCR-LE Series is from 15μs to 70μs, the high peak current may flow depending on the capacitor size. To prevent it, turn Soft Start on to decrease the peak current.
    2-2 Surge Suppression Function
    Generally, if the output is suddenly interrupted, the L-load releases energy. It means that;
    1) It becomes the high impedance state due to the sudden interruption. 2) The L-load generates the surge voltage and it is biased to the power supply as overvoltage.
    To prevent it, PCR-LE Series features the Surge Suppression function. When OUTPUT is turned off while Surge Suppression is set to ON (factory default setting), the output voltage stays at 0V for approx. 200μs and then the output impedance becomes high.
    For C-load or capacitive DUT:
    Surge Suppression is ON: If OUTPUT is turned off in DC mode, the output voltage rapidly falls (see Fig. 3) and the current flows from DUT to PCR-LE Series.
    Surge Suppression is OFF: See Fig.4. This is equivalent to having the interruption due to wiring disconnection. It may meet the requirements of IEC6100-4-29 (interruption in high impedance state).

    2-3 Response Speed

    PCR-LE Series uses a high-speed linear amplifier to provide high-quality/high-stability output. It can freely control the broadband waveform; however the output may become unstable depending on the capacitive load capacity or wiring conditions. To improve it, you can set the response speed of the internal amplifier to SLOW.
    Response speed mode for PCR-LE Series:
    Rated power capacity is 4kVA or less: FAST, MEDIUM, SLOW Rated power capacity is 6kVA or more: MEDIUM, SLOW

    Products Mentioned In This Article:

    PCR-LE Series please see HERE

  • Which Power Supply is Most Suitable to Run DC Motor?

    When choosing a power supply to run a DC motor, the first and most important thing you need to consider is a maximum current that your motor will use. DC motor typically requires a startup current which is quite a lot higher than its running current. Due to this, not all DC power supplies can provide sufficient power to DC motors.
    In this white paper, we will take a look at the capability of our bipolar DC power supply PBZ20-20A, which can supply a short-term peak current up to six times its rating current (± 120 Apk CV).
    Below, we are going to share our measurement results that show how PBZ20-20A worked with a DC motor.
    1. Purpose of Measurement
    The purpose of this measurement is to determine the performance of PBZ20-20A on a brushed DC motor by measuring the voltage and current waveforms.
    2. Wiring Connection

    ▪ Each was crimped: the positive ends and negative ends of output and remote sensing wires. ▪ Wiring length: Approx. 1 m for both remote sensing and output wiring
    ▪ Wiring cross section: Output wiring: AWG16 1.31 mm² (1.25 sq),
    Remote sensing wiring:AWG24 0.205 mm² (0.2 sq)
    ▪ The twisted pair was made on the output and remote sensing wire. 3. Measurement Conditions
    ▪ Output mode: CV mode
    ▪ Response setting: CV mode voltage response: 3.5 μs/100 μs, CC mode current response: 35 μs/1 ms * PBZ20-20A can output a peak current only when the current response is set to 1 microsecond in CV
    mode.
    ▪ Limit setting: Voltage limit: + 14 V (protect the motor from overvoltage),
    Current limit: ± 22 A (output current setting: max.)
    ▪ Voltage setting: 12 Vdc
    ▪ Motor to be used: Brushed DC motor – details unknown.

    4. Results
    1) Response setting: CV 3.5 μs, CC 35 μs

    ▪ The motor voltage was oscillated because the output current was limited (no peak current was provided).
    2) Response setting: CV 100 μs, CC 1ms

    ▪ CV mode voltage response setting was changed: 3.5 μs to 100 μs. ▪ CC mode current response setting was changed: 35 μs to 1 ms.
    ▪ Since the current response was set to 1 microsecond, PBZ20-20A could output the peak current. ▪ The voltage oscillation was reduced.
    3) Response setting: CV 100 μs, CC 1ms with remote sensing turned on

    ▪ With the remote sensing turned on, the voltage became more stable.

    4) When the output was turned off:

    ▪ When the output was turned off, the followings happened;
    1) The reverse motor current was generated and then interrupted. It took approx. 10 microseconds.
    2) The motor voltage started to rise.
    3) The overvoltage protection (OVP ALM) was activated.
    The reason why this happened was because the PBZ20-20A’s relay contact was suddenly opened (disconnected).

    5) Extended view of No. 4

    ▪ The motor voltage reached approx. 28 Vdc max.
    6) When the motor voltage was changed from 12 Vdc to 0 Vdc by the sequence control:

    ▪ The voltage rising was not found under the sequence control.
    7) After the output was turned off:

    ▪ Until the motor was fully stopped, the motor reverse voltage had been applied to PBZ20-20A.
    ▪ The voltage detection circuit in PBZ20-20A kept closed (connected) even when the output was turned off. This could be a small path to allow a little bit of motor reverse current (discharging current) to flow back to PBZ20-20A.
    5. Measurement Summary
    ▪ When the PBZ20-20A’s output was turned off, the brushed DC motor started functioning like a generator inverting the direction of its current and forcing it into PBZ20-20A.
    ▪ As an explanation of measurement No. 4; when the output was turned off, the reverse current flew for approx. 10 microseconds. However, the output relay contact in PBZ20-20A was open, so there was no path for the current to flow. This sudden release of energy induced the transient voltage spike.
    ▪ PBZ20-20A provided the peak current at 45 A for the brushed DC motor. The duration that the output current exceeded 20 A was approx. 8 microseconds.
    6. Recommendation
    ▪ Bipolar power supply can sink a reverse current, while DC power supply cannot. If using a DC power supply and motor, connect an electronic load in parallel to absorb a reverse current.
    ▪ To protect PBZ20-20A from an overvoltage, wait until an output current reaches 0 A before turning an output off.
    7. Conclusion
    The above measurement results prove that PBZ20-20A can meet the requirement to run the DC motor to be tested. To identify whether PBZ20-20A can sufficiently power your DC motor or not, we recommend that you carefully read the data sheets or check the specifications.

    Products Mentioned In This Article:

    • PBZ Series please see HERE
  • How to Balance Battery Module Charge-Discharge

    With the recent diversification of battery module application such as for automotive and backup, more and more users want to conduct a battery module charge-discharge test, besides of an individual cell battery test.
    As a battery management system has been greatly developed to maximize battery’s capacity, the practical needs to perform evaluations on balancing battery charge-discharge are increased. Here you will find the method to balance the battery charge-discharge by using our DC power supply and electronic load.

    Unbalancing Battery Module Charge

    CC flows into each cell with different capacity and SOC unbalance. Cells with less charge capacity always reach the charge cut-off voltage faster. → The battery module cannot reach its full capacity.

    Unbalancing Battery Module Discharge

    CC is sunk from each cell with different capacity and SOC unbalance. Cells with less discharge capacity always reach the discharge cut-off voltage faster. → The battery module cannot be fully discharged.

    Balancing Battery Module Charge-Discharge

    Electronic loads are separately connected to each cell in parallel to perform the balancing charge-discharge.

    Balancing Battery Module Charge
    Electric loads connected to each cell in parallel operate in CV mode.
    Balancing and optimal charge to series cells is available by performing the CC-CV charge; The CC setting is set to a DC power supply and the CV setting is set to electronic loads.
    Note: 1) The CC limit for electronic loads should be set higher than the charge current. 2) The electronic load alarm should be linked to the power supply output.

    Balancing Battery Module Discharge
    Electric loads connected to each cell in parallel operate in CC mode independently.
    To stop the discharge; 1) Set the discharge cut-off voltage as under voltage protection (UVP) to turn the load off. 2) Set the discharge cut-off voltage as the CV set value to perform the CC+CV operation. Note: 1) The negative input terminal in each electronic load should be isolated. 2) With the external analogue control, the control signal terminal should be isolated.

    Products Mentioned In This Article:

    • DC Power Supplies & Electronic Loads please click HERE
  • DC Power Supply Sinks Current when Output is Turned Off

    When using a DC power supply for charging a load such as battery or capacitor, it is important to note that the DC power supply absorbs a current from such loads when the output is turned off. Here we are going to further explain this power supply’s behaviour; DC power supply, in general, comprises a bleeder circuit to discharge a power supply’s electrolytic capacitor at its output terminal. If the output is turned off after charging a battery or capacitor, the bleeder circuit sinks the current from them. The purpose of the bleeder circuit is to quickly discharge the voltage stored in the power supply’s electrolytic capacitor for safety reasons.
    Now look at the following figures. Figure 1 shows the equivalent circuit of the DC power supply output and Figure 2 shows the example of the sink current measurement. This example data may help you estimate a discharge current and voltage change of your load.
    1. Equivalent Circuit of DC Power Supply: When output is turned off
    As shown in Figure 1, the sink current (shown in red arrows) flows through the 39-kΩ resistance and voltage-following constant current circuit (CC varies by voltage).
    Sink current

    2. Sink Current: When output is turned off
    Figure 2 is the example of the sink current measurement through above resistance and circuit

    When the DC power supply is turned off, the sink current flows through the 39-kΩ resistance only.

    Products Mentioned In This Article:

    • DC Power Supplies please see HERE
  • How to use the voltage correction function on frequency response

    The PCR-WE can output up to 5 kHz, but it has frequency response as shown in the figure below. The response is about -3dB at 5kHz. For example, the waveform in the figure below is for 120 Vrms, 5 kHz.

    Voltage amplitude correction
    The PCR-WE has a function to correct the attenuation due to the frequency response of the output. Please refer to the “The soft sensing function is used” page of the User’s Manual.
    Steps to enable features:
    1. Turn off the Output.
    2. Set the Output Voltage.
    3. Press Oher button (Shift + Memory) > 1/2 (F6) > COMPEN (F2) > SENS.-S (F3).
    4. Press ENT.
    “SENS.-S” is displayed on the panel.
    5. Press 1/2 (F6) > SOFT.SENS (F2) > S.POINT (F5) > O.TERM (F2)

    Set the sensing point in output terminal. 6. Press ESC > V.CTRL (F2) > AC (F2)

    Corrected waveform
    The output voltage is 120 Vrms.

    Products Mentioned In This Article:

    • PCR-WE Series please see HERE
  • DC Electronic Load – Part 1: What is a DC Electronic Load?

    Beginners who have never used an electronic load may well get confused with the difference between electronic loads and power supplies. They sometimes wonder ‘why the electronic load does not provide any output…?’
    While similar in appearance, electronic loads are totally different from power supplies. It is not often you get to see them but it is suitable for specific applications such as working as variable resistors, in a part of high-power systems, to test power supplies.
    From here we offer a great series of white papers that give you a thorough understanding of the basics and use of electronic loads, ranged from what it is through to how it is used including its operating principle. Part 1 explores the fundamentals of electronic loads.
    * This series focuses on explaining DC electronic loads only; AC electronic loads will not be included.
    1. Fundamentals of DC Electronic Load
    DC electronic loads are used in a range of DC power supply tests. We will discuss why they are ideally suited for power source testing, in contrast with a popular device, DC power supply.
    1-1. Electronic Load and Load of Horse-Drawn Vehicle
    Electronic loads can help you investigate the ability of power supplies. This can be compared to the method of determining an ability of a cart horse. Figure 1-1 shows that the horse is pulling the cart of mass 490 kg (approx.1080 lb). If the horse cannot pull a cart of mass 500 kg (approx. 1102 lb), it proves that this horse has the ability of pulling the cart up to 490 kg (approx.1080 lb).

    You now understand how electronic loads are different from power supplies; power supplies apply a voltage to DUTs, while electronic loads sink a current from DUTs. So you can now really understand the answer to ‘why electronic loads do not provide any output…?’
    1-2. Act as Substitute for High-Power Components
    Electronic loads are used to test power source devices. According to Ohm’s law, if the resistor is connected to the output of the power source device (DUT), the current flows from the DUT (See Figure 1-3). Electronic loads can be used as substitute for the resistor. Furthermore, users can easily adjust the resistance value on their own from electronic loads.

    In other words, electronic loads can act as a variable resistor, and also achieve tens of kilowatts of power. Instead of using different sizes of fixed resistors, one unit of electronic load allows you test the load dynamically in a repeatable fashion.
    Electronic load circuits regulate the resistance value. Based on the performance of circuit functions, electronic loads behave like a 1) Variable resistor 2) Variable Zener diode 3) Load simulator, which described in more detail in the following sections.
    1) Act as Variable Resistor
    Figure 1-4 shows that the variable resistor is connected to the DUT.
    Figure 1-5 shows the relationship between the voltage (V) across the resistor and resistor’s current (I). This relationship in a circuit of the resistor produces a straight line. In the graph, the resistance (R) is the slope. The slope varies according to the resistance value.
    During the DC power supply tests, the electronic load controls the resistor’s current by adjusting the resistance value.

    The most important aspect is that “the variable resistor can regulate the current flow in the circuit.” If the electronic load acts as a variable resistor, it means that you can control the current based on your test applications or conditions with electronic loads. Furthermore, electronic loads have a capability to provide a constant power or constant current mode, which are described in the next article.
    2) Act as Variable Zener Diode
    Figure 1-6 shows that the Zener diode is connected to the DUT.
    Figure 1-7 shows the relationship between the voltage across the Zener diode and its current. Once the voltage reaches a certain point known as the Zener voltage (Vz), the Zener resistance dramatically decreases. The Zener diode clips any voltage that exceeds the Zener voltage (Vz). In an electronic load, you can set a voltage (equivalent to the Zener voltage) that remains constant regardless of changes to its input current (I). This set voltage is called the constant voltage (CV) and this operation is called the CV mode.

    If the DUT is motor in figure 1-6, the DUT may provide a regenerative power by reversing the direction of the motor rotation and it may cause a reverse voltage spike. To prevent it, set the CV voltage so that the voltage will not exceed this CV set voltage.
    3) Act as Load Simulator
    High-performance electronic loads can simulate various power states so they can be used in diverse applications instead of using a real load. You just select an appropriate electronic load that can exactly simulate your actual load with the waveforms in the example below;
    Figure 1-8 shows that the test waveform current flows on a circuit.
    Figure 1-9 shows the current waveform simulation example for lamp current.
    Figure 1-10 shows the pulsed current waveform simulation example.

    Products Mentioned In This Article:

    Kikusui Electronic Loads please see HERE